5 research outputs found

    Investigating Real-World Benefits of High-Frequency Gain in Bone-Anchored Users with Ecological Momentary Assessment and Real-Time Data Logging

    Get PDF
    Purpose: To compare listening ability (speech reception thresholds) and real-life listening experience in users with a percutaneous bone conduction device (BCD) with two listening programs differing only in high-frequency gain. In situ real-life experiences were recorded with ecological momentary assessment (EMA) techniques combined with real-time acoustical data logging and standard retrospective questionnaires. Methods: Nineteen experienced BCD users participated in this study. They all used a Ponto 4 BCD from Oticon Medical during a 4-week trial period. Environmental data and device parameters (i.e., device usage and volume control) were logged in real-time on an iPhone via a custom iOS research app. At the end of the trial period, subjects filled in APHAB, SSQ, and preference questionnaires. Listening abilities with the two programs were evaluated with speech reception threshold tests. Results: The APHAB and SSQ questionnaires did not reveal any differences between the two listening programs. The EMAs revealed group-level effects, indicating that in speech and noisy listening environments, subjects preferred the default listening program, and found the program with additional high-frequency gain too loud. This finding was corroborated by the volume log-subjects avoided the higher volume control setting and reacted more to changes in environmental sound pressure levels when using the high-frequency gain program. Finally, day-to-day changes in EMAs revealed acclimatization effects in the listening experience for ratings of "sound quality" and "program suitability" of the BCD, but not for ratings of "loudness perception" and "speech understanding". The acclimatization effect did not differ among the listening programs. Conclusion: Adding custom high-frequency amplification to the BCD target-gain prescription improves speech reception in laboratory tests under quiet conditions, but results in poorer real-life listening experiences due to loudness.</p

    Investigating Real-World Benefits of High-Frequency Gain in Bone-Anchored Users with Ecological Momentary Assessment and Real-Time Data Logging

    Get PDF
    Purpose: To compare listening ability (speech reception thresholds) and real-life listening experience in users with a percutaneous bone conduction device (BCD) with two listening programs differing only in high-frequency gain. In situ real-life experiences were recorded with ecological momentary assessment (EMA) techniques combined with real-time acoustical data logging and standard retrospective questionnaires. Methods: Nineteen experienced BCD users participated in this study. They all used a Ponto 4 BCD from Oticon Medical during a 4-week trial period. Environmental data and device parameters (i.e., device usage and volume control) were logged in real-time on an iPhone via a custom iOS research app. At the end of the trial period, subjects filled in APHAB, SSQ, and preference questionnaires. Listening abilities with the two programs were evaluated with speech reception threshold tests. Results: The APHAB and SSQ questionnaires did not reveal any differences between the two listening programs. The EMAs revealed group-level effects, indicating that in speech and noisy listening environments, subjects preferred the default listening program, and found the program with additional high-frequency gain too loud. This finding was corroborated by the volume log—subjects avoided the higher volume control setting and reacted more to changes in environmental sound pressure levels when using the high-frequency gain program. Finally, day-to-day changes in EMAs revealed acclimatization effects in the listening experience for ratings of “sound quality” and “program suitability” of the BCD, but not for ratings of “loudness perception” and “speech understanding”. The acclimatization effect did not differ among the listening programs. Conclusion: Adding custom high-frequency amplification to the BCD target-gain prescription improves speech reception in laboratory tests under quiet conditions, but results in poorer real-life listening experiences due to loudness

    Benefit of Higher Maximum Force Output on Listening Effort in Bone-Anchored Hearing System Users:A Pupillometry Study

    No full text
    Objectives: The aim of this study was to compare listening effort, as estimated via pupillary response, during a speech-in-noise test in bone-anchored hearing system (BAHS) users wearing three different sound processors. The three processors, Ponto Pro (PP), Ponto 3 (P3), and Ponto 3 SuperPower (P3SP), differ in terms of maximum force output (MFO) and MFO algorithm. The hypothesis was that listeners would allocate lower listening effort with the P3SP than with the PP, as a consequence of a higher MFO and, hence, fewer saturation artifacts in the signal. Design: Pupil dilations were recorded in 21 BAHS users with a conductive or mixed hearing loss, during a speech-in-noise test performed at positive signal-to-noise ratios (SNRs), where the speech and noise levels were individually adjusted to lead to 95% correct intelligibility with the PP. The listeners had to listen to a sentence in noise, retain it for 3 seconds and then repeat it, while an eye-tracking camera recorded their pupil dilation. The three sound processors were tested in random order with a single-blinded experimental design. Two conditions were performed at the same SNR: Condition 1, where the speech level was designed to saturate the PP but not the P3SP, and condition 2, where the overall sound level was decreased relative to condition 1 to reduce saturation artifacts. Results: The P3SP led to higher speech intelligibility than the PP in both conditions, while the performance with the P3 did not differ from the performance with the PP and the P3SP. Pupil dilations were analyzed in terms of both peak pupil dilation (PPD) and overall pupil dilation via growth curve analysis (GCA). In condition 1, a significantly lower PPD, indicating a decrease in listening effort, was obtained with the P3SP relative to the PP. The PPD obtained with the P3 did not differ from the PPD obtained with the other two sound processors. In condition 2, no difference in PPD was observed across the three processors. The GCA revealed that the overall pupil dilation was significantly lower, in both conditions, with both the P3SP and the P3 relative to the PP, and, in condition 1, also with the P3SP relative to the P3. Conclusions: The overall effort to process a moderate to loud speech signal was significantly reduced by using a sound processor with a higher MFO (P3SP and P3), as a consequence of fewer saturation artifacts. These findings suggest that sound processors with a higher MFO may help BAHS users in their everyday listening scenarios, in particular in noisy environments, by improving sound quality and, thus, decreasing the amount of cognitive resources utilized to process incoming speech sounds.Funding Agencies|Oticon Medical AB (Askim, Sweden)</p

    Consensus statement on bone conduction devices and active middle ear implants in conductive and mixed hearing loss

    No full text

    Consensus Statement on Bone Conduction Devices and Active Middle Ear Implants in Conductive and Mixed Hearing Loss.

    Get PDF
    Nowadays, several options are available to treat patients with conductive or mixed hearing loss. Whenever surgical intervention is not possible or contra-indicated, and amplification by a conventional hearing device (e.g., behind-the-ear device) is not feasible, then implantable hearing devices are an indispensable next option. Implantable bone-conduction devices and middle-ear implants have advantages but also limitations concerning complexity/invasiveness of the surgery, medical complications, and effectiveness. To counsel the patient, the clinician should have a good overview of the options with regard to safety and reliability as well as unequivocal technical performance data. The present consensus document is the outcome of an extensive iterative process including ENT specialists, audiologists, health-policy scientists, and representatives/technicians of the main companies in this field. This document should provide a first framework for procedures and technical characterization to enhance effective communication between these stakeholders, improving health care